The Detection Kit for Porcine Deltacoronavirus Disease Virus is applicable to detect the PDCoV RNA in Pig serum, plasma, intestinal tissue, intestinal contents, Mesentery lymph nodes and excreta samples. The test results are for research purposes only and not for clinical diagnosis.
 
Advantages:
1. GMP, ISO 9001 certificates
2. The product is evaluated by National Avian Influenza Laboratory of China Animal Health and Epidemiology Center.
3. High stability and effectiveness.
4. Customization & Multiple packaging
Availability:

Real-time PCR Detection Kit for Porcine Deltacoronavirus Disease Virus

(Product Name) Real-time PCR Detection Kit for Porcine Deltacoronavirus Disease Virus.

(Package) 50 kits/box

(Indication) The Detection Kit for Porcine Deltacoronavirus Disease Virus is applicable to detect the PDCoV RNA in Pig serum, plasma, intestinal tissue, intestinal contents, Mesentery lymph nodes and excreta samples. The test results are for research purposes only and not for clinical diagnosis.

(Main components and content)

Name

Specification

Quantity

PDCoV Reaction Solution

1000µl/Tube

1

PDCoV Positive Control

250µl/Tube

1

Negative Control

250µl/Tube

1

(Storage and Shelf Life)

Stored at -20±5℃, Repeated freezing and thawing ≤ 3 times, the shelf life is 12 months.

(Test Method)

1. Nucleic Acid Extraction

A commercialized DNA/RNA extraction kit can be carried out for nucleic acid extraction, please follow the instruction of the kit.

2. PCR amplification

2.1 Calculate the number of test samples, take n+2 PCR reaction tubes, and add 20µl to of reaction solution to each tube.

2.2 Add 5µl nucleic acid of negative control, positive control and samples into the above PRC reaction tubes respectively, centrifuge at 8000rpm for several seconds, and put them into the fluorescent quantitative PCR amplifier.

2.3 The reaction conditions shall be set as:

Parameters of amplification

System

The total volume is 25µl

Signal collection

PDCoV fluorescence signal

CY5 channel collects fluorescence signal

Reaction Conditions of PCR

Phase

Conditions

Cycles

UNG Process

55℃ for 15 minutes

1

Pre-denaturation

95℃ for 30 seconds

1

PCR

95℃ for 10 seconds

40

60℃ for 30 seconds

Set to collect the fluorescent signal at the end of this phase

[Interpretation of the results]

1. The validity judgement:

1.1 Positive Control: The Ct value of the CY5 channel ≤ 32, and the amplification curve has a significant exponential growth phase.

1.2 Negative Control: CY5 channel has no amplification curve, or the amplification curve is a straight line or slightly oblique line.

2. The test result judgement:

If the FAM detection channel of the test sample has no amplification curve, it can be determined as PDCoV negative.

If the FAM detection channel has an exponential growing amplification curve and the Ct value is 36, it can be determined as PDCoV positive.

36<Ct Value<40 samples should be considered as doubtful results, and the analysis should be repeated for confirmation.

[Precautions]

1. The laboratory management shall strictly follow the management specification of PCR gene amplification laboratory. The laboratory personnel must be trained professionally. The experiment process shall be conducted strictly in different areas (Reagent preparation area, specimen preparation area, amplification and product analysis area). All consumables shall be disposable after sterilization. Special apparatus, equipment and supplies at each stage of the experiment operation shall not be cross-used.

2. Please prepare the biological safety cabinet for the reagent and specimen preparation stage. The Lab coat, disposable gloves and pipette shall be carried out during the experiment.

3. Repeated freezing&thawing of reagents shall be avoided as far as possible. Before use, the reagents shall be completely thawed and centrifuged at 8000rpm for several seconds.

4. Please put the pipette used in the specimen preparation area into the container containing disinfectant and discard it with the waste after sterilization.

5. After the experiment, the worktable and pipette shall be treated with 10% hypochlorite or 75% alcohol or ultraviolet lamp.

[Manufacture]

Name: Shandong Xinda Gene Technology Co., Ltd

A subsidiary of the Shandong Sinder Technology Co., Ltd

Address: Building B2, Bandaohuigu Industrial Park, Shungeng Road, Zhucheng City, Shandong Province

Post Code: 262233

Phone: +86 - 0532 5882 0810


Previous: 
Next: 
Inquiry

Product Category

Shandong Sinder Technology Co., Ltd is a China animal health joint venture company with SUMITOMO JAPAN that develops, manufactures and markets a broad range of veterinary medicines and services.

Quick Links

Follow Us

 NO.195, Shungeng Road, Zhucheng City, Shandong Province, China
 +86-13780641230
 +86-532-58820810
 sinder@sindergroup.cn
Contact us
Copyright © 2023 Shandong Sinder Technology Co., Ltd. All rights reserved.  Sitemap  Support by Leadong  Privacy Policy